Short Description: 
LYD-40 series spark gap power surgeprotector is designed and manufactured according to IEC61643-11 and GB18802.1standards. The product has high lightning current discharge capacity, up to50kA (10 350μS), which can prevent direct lightning strikes and other surgecurrent. This product can be mounted on a standard 35mm DIN rail mounting, ithas high safety factor and long service life, it can be applied to single-phaseor three-phase power supply in the class I lightning protection of equipmentand power system with high lightning risk.
Features
· Protecting low-voltage consumers’installations against indirect lightning discharges
· High performance varistor with thermaldisconnection tripping device
· Plug-in module/base design facilitatereplacement of a failed module without the need to remove system wiring etc.
· Protection class: Type 2,Class I
· Pole number:4P
· surge areeare used to guard sensitiveequipments from voltage spike
Application:
LYD-40 series spark gap power surgeprotector is designed and manufactured according to IEC61643-11 and GB18802.1standards. The product has high lightning current discharge capacity, up to50kA (10 350μS), which can prevent direct lightning strikes and other surgecurrent. This product can be mounted on a standard 35mm DIN rail mounting, ithas high safety factor and long service life, it can be applied to single-phaseor three-phase power supply in the class I lightning protection of equipmentand power system with high lightning risk.
- Class II / Type 2 lightning protectivedevice.
– Consisting of a base part and 4 MOV plug-in protection modules.
– For using in the lightning protection zones concept at boundary 1-2.
– The core parts are metal oxide vristor components with high dischargecapacity.
– Low residual voltage and quick response
– Reliable control thanks to Thermo Dynamic Control disconnector.
– With remote signaling contact for control device.
– Fault indication via red mark in the inspection window.
– Protection mode: L/N-PE.
Technology characteristic
Product characteristics
| Specification | LY1-40 | 
| Item name | Surge protection | 
| SPD dassification according to EN61643-11 | Type 2 | 
| power system | TT-TN-IT | 
| Nominal voltage | 220/380V | 
| Max. continuous operating a.c. voltage Uc | 275/320/385V | 
| Norminal discharge current (8/20μs) In | 20kA | 
| Max. discharge current(8/20us) Imax | 40kA | 
| Voltage protection level UP | 1.3/1.5/1.8 kV | 
| Remote communication alarm | selectable | 
| Operating state/ fault indication | green/ red | 
| Cross-section area | 4-35mm2 | 
| For mounting on | 35mm Din rail | 
| Degree of protection | IP20 | 
| Operating temperature range Tu | -40~70℃ | 
| Enclosure material | Thermal plastic UL94-V0 |